Charging time with
30A PAC charger
|
Code switch position.
|
Battery
|
Charging current
|
20% depth of discharge
|
50% depth of discharge
|
80% depth of discharge
|
|
0
|
|
|
|
|
|
|
1
|
Unsealed 110Ah
|
30 A
|
2 h
|
4½ h
|
8 h
|
|
2
|
Unsealed 130 Ah
|
30 A
|
2 h
|
5 h
|
8½ h
|
|
3
|
Unsealed 160 Ah
|
30 A
|
2½ h
|
5½ h
|
9½ h
|
|
4
|
Unsealed 190Ah
|
30 A
|
2½ h
|
8 h
|
10 h
|
|
5
|
Unsealed 230 Ah
|
30 A
|
3 h
|
8½ h
|
11½ h
|
|
6
|
Unsealed 275 Ah
|
30 A
|
3½ h
|
9½ h
|
12½ h
|
|
7
|
Unsealed 325 Ah
|
30 A
|
4 h
|
10½ h
|
14 h
|
|
8
|
|
|
|
|
|
|
9
|
Sealed 325 Ah
|
30 A
|
6 h
|
11 h
|
14½ h
|
|
10 = A
|
Sealed 275 Ah
|
30 A
|
5½ h
|
10 h
|
13½ h
|
|
11 = B
|
Sealed 230 Ah
|
30 A
|
5 h
|
9½ h
|
12 h
|
|
12 = C
|
Sealed 190 Ah
|
30 A
|
4½ h
|
8½ h
|
11 h
|
|
13 = D
|
Sealed 160 Ah
|
25 A
|
4 h
|
8 h
|
10½ h
|
|
14 = E
|
Sealed 130 Ah
|
21 A
|
3½ h
|
7 h
|
9½ h
|
|
15 = F
|
Sealed 110 Ah
|
17 A
|
3½ h
|
6½ h
|
9 h
|
This timetable equals with algorithms used in programs E110 ja E112.
Charging time with
20A PAC charger
|
Code switch position.
|
Battery
|
Charging current
|
20% depth of discharge
|
50% depth of discharge
|
80% depth of discharge
|
|
0
|
Unsealed 55 Ah
|
11 A
|
2½ h
|
5½ h
|
9½ h
|
|
1
|
Unsealed 70 Ah
|
14 A
|
2½ h
|
5½ h
|
9½ h
|
|
2
|
Unsealed 90 Ah
|
17 A
|
2½ h
|
6 h
|
9½ h
|
|
3
|
Unsealed 110 Ah
|
20 A
|
2½ h
|
6 h
|
10 h
|
|
4
|
Unsealed 130 Ah
|
20 A
|
3 h
|
8 h
|
10½ h
|
|
5
|
Unsealed 160Ah
|
20 A
|
3½ h
|
9 h
|
11½ h
|
|
6
|
Unsealed 190 Ah
|
20 A
|
4 h
|
10 h
|
13 h
|
|
7
|
Unsealed 230 Ah
|
20 A
|
4½ h
|
10½ h
|
14½ h
|
|
8
|
Sealed 50 Ah
|
6.5 A
|
5 h
|
9½ h
|
12½ h
|
|
9
|
Sealed 70 Ah
|
9.1 A
|
5 h
|
9½ h
|
12½ h
|
|
10 = A
|
Sealed 105 Ah
|
13.6 A
|
5 h
|
9½ h
|
12½ h
|
|
11 = B
|
Sealed 160 Ah
|
20 A
|
5 h
|
9½ h
|
12½ h
|
|
12 = C
|
Sealed 180 Ah
|
20 A
|
5½ h
|
10 h
|
13½ h
|
|
13 = D
|
|
|
|
|
|
|
14 = E
|
|
|
|
|
|
|
15 = F
|
|
|
|
|
|
This timetable equals with algorithms used in programs E020 ja E021.
Genesis Batteries Charging
time with 30A PAC charger
|
Code switch position.
|
Battery
|
Charging current
|
20% depth of discharge
|
50% depth of discharge
|
80% depth of discharge
|
|
0
|
12V Genesis 13 Ah
|
20A
|
1h 20min
|
1h 50min
|
2h 20min
|
|
1
|
12V Genesis 16 Ah
|
25A
|
1h 20min
|
1h 50min
|
2h 20min
|
|
2
|
12V Genesis 26 Ah
|
30A
|
1h 25min
|
2h 5min
|
2h 45min
|
|
3
|
12V Genesis 32 Ah
|
30A
|
1h 30min
|
2h 20min
|
3h 10min
|
|
4
|
12V Genesis 42 Ah
|
30A
|
1h 45min
|
2h 45min
|
3h 50min
|
|
5
|
12V Genesis 70 Ah
|
30A
|
2h 10min
|
4h
|
5h 40min
|
|
6
|
|
|
|
|
|
|
7
|
|
|
|
|
|
|
8
|
24V Genesis 13 Ah
|
20A
|
1h 20min
|
1h 50min
|
2h 20min
|
|
9
|
24V Genesis 16 Ah
|
25A
|
1h 20min
|
1h 50min
|
2h 20min
|
|
10 = A
|
24V Genesis 26 Ah
|
30A
|
1h 25min
|
2h 5min
|
2h 45min
|
|
11 = B
|
24V Genesis 32 Ah
|
30A
|
1h 30min
|
2h 20min
|
3h 10min
|
|
12 = C
|
24V Genesis 42 Ah
|
30A
|
1h 45min
|
2h 45min
|
3h 50min
|
|
13 = D
|
24V Genesis 70 Ah
|
30A
|
2h 10min
|
4h
|
5h 40min
|
|
14 = E
|
|
|
|
|
|
|
15 = F
|
|
|
|
|
|
This timetable equals with Genesis battery charging algorithms used in program W114.
POWERFINN OY
Perämiehenkatu 6
FIN-24100 Salo |
Tel: +358 (0)2 777 290
Fax: +358 (0)2 777 2918
http://www.powerfinn.fi
|
|